PhoXi 3D scanners family

From 3D scanning Knowledge base - Photoneo wiki
Revision as of 17:14, 4 April 2017 by Marcel (talk | contribs) (General specification: parameters explanation)

Jump to: navigation, search

General specification

Projection unit
Light source Visible red light (laser)
Wavelength 638nm
Laser class 3R (IEC / EN 60825-1, 2014)
Peak / CW Power 314uW
Pulse Energy 382nJ
Pulse Length 960us
Projection angle horizontal 47.5° ±1°
Projection angle vertical 36.0° ±2°

For model/size specific parameters see our product showcase.

Specification Parameters Explanation

Point size
The distance between two measured points on the plane perpendicular to the camera in the focus distance from the camera.
Absolute accuracy
The precision of point measurement. It is the standard deviation of the measurement error in the whole measuring range of the device.
Z noise
The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution.

Connectivity

Connectivity v1.png

Installation

1. Mount the scanner, connect it to the power source and ethernet.

2. Run the installer packed in the archive and follow the on-screen instructions

3. Run PhoXiControl.exe using shortcut or under Program Files/PhotoneoPhoXiControl/bin

CAD data

Contains 3D Scanner body and its scanning volume as a solid object.

Available CAD for download:

PhoXi Scanner S + scanning volume
PhoXi Scanner M + scanning volume
PhoXi Scanner L + scanning volume

ScanningVolume.png

Mounting plate drawing

MountingPlateDrawing.png