== General specification ==
 
{| class="wikitable"
 
{| class="wikitable"
Line 28: Line 31:
 
|}
 
|}
  
For model/size specific parameters see our [http://www.photoneo.com/product-showcase/phoxi_3d_scanners/ product showcase].
+
For model/size specific parameters see our '''[http://www.photoneo.com/product-showcase/phoxi_3d_scanners/ product showcase]'''.
  
 
=== Specification Parameters Explanation ===
 
=== Specification Parameters Explanation ===
Line 58: Line 61:
 
== Connectivity ==
 
== Connectivity ==
 
[[File:Connectivity v1.png|800px]]
 
[[File:Connectivity v1.png|800px]]
 
== Installation ==
 
 
1. Mount the scanner, connect it to the power source and ethernet.
 
 
2. Run the installer packed in the archive and follow the on-screen instructions
 
 
3. Run PhoXiControl.exe using shortcut or under Program Files/PhotoneoPhoXiControl/bin
 
  
 
== CAD data ==
 
== CAD data ==

Revision as of 17:15, 15 May 2017

This page contains technical description of PhoXi 3D Scanners. For scanning guide, see Scanning best practices.

General specification

Projection unit
Light source Visible red light (laser)
Wavelength 638nm
Laser class 3R (IEC / EN 60825-1, 2014)
Peak / CW Power 314uW
Pulse Energy 382nJ
Pulse Length 960us
Projection angle horizontal 47.5° ±1°
Projection angle vertical 36.0° ±2°

For model/size specific parameters see our product showcase.

Specification Parameters Explanation

Depth Map resolution
Maximum number of measured points (the resolution of camera sensor)
Point size
The distance between two measured points on the plane perpendicular to the camera in the focus distance from the camera.
Absolute accuracy
The precision of point measurement. It is the standard deviation of the measurement error in the whole measuring range of the device.
Z noise
The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution.
FPS
Maximum number of triggered frames per second, in fastest acquisition mode
Data acquisition time - best case
Fastest possible acquisition time
Data acquisition time - worst case
Longest expected acquisition time (bad lighting conditions, dark shiny objects)
3D points throughput
Number of 3D points that can be reconstructed in a second in sequential scans

Connectivity

Connectivity v1.png

CAD data

Contains 3D Scanner body and its scanning volume as a solid object.

Available CAD for download:

PhoXi Scanner S + scanning volume
PhoXi Scanner M + scanning volume
PhoXi Scanner L + scanning volume

ScanningVolume.png

Mounting plate drawing