Difference between revisions of "PhoXi 3D scanners family"

From 3D scanning Knowledge base - Photoneo wiki
Jump to: navigation, search
(General specification: parameters explanation)
(Specification Parameters Explanation)
Line 31: Line 31:
  
 
=== Specification Parameters Explanation ===
 
=== Specification Parameters Explanation ===
 +
 +
;Depth Map resolution
 +
:Maximum number of measured points (the resolution of camera sensor)
  
 
;Point size
 
;Point size
Line 40: Line 43:
 
;Z noise
 
;Z noise
 
:The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution.
 
:The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution.
 +
 +
;FPS
 +
:Maximum number of triggered frames per second, in fastest acquisition mode
 +
 +
;Data acquisition time - best case
 +
:Fastest possible acquisition time
 +
 +
;Data acquisition time - worst case
 +
:Longest expected acquisition time (bad lighting conditions, dark shiny objects)
 +
 +
;3D points throughput
 +
:Number of 3D points that can be reconstructed in a second in sequential scans
  
 
== Connectivity ==
 
== Connectivity ==

Revision as of 16:01, 15 May 2017

General specification

Projection unit
Light source Visible red light (laser)
Wavelength 638nm
Laser class 3R (IEC / EN 60825-1, 2014)
Peak / CW Power 314uW
Pulse Energy 382nJ
Pulse Length 960us
Projection angle horizontal 47.5° ±1°
Projection angle vertical 36.0° ±2°

For model/size specific parameters see our product showcase.

Specification Parameters Explanation

Depth Map resolution
Maximum number of measured points (the resolution of camera sensor)
Point size
The distance between two measured points on the plane perpendicular to the camera in the focus distance from the camera.
Absolute accuracy
The precision of point measurement. It is the standard deviation of the measurement error in the whole measuring range of the device.
Z noise
The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution.
FPS
Maximum number of triggered frames per second, in fastest acquisition mode
Data acquisition time - best case
Fastest possible acquisition time
Data acquisition time - worst case
Longest expected acquisition time (bad lighting conditions, dark shiny objects)
3D points throughput
Number of 3D points that can be reconstructed in a second in sequential scans

Connectivity

Connectivity v1.png

Installation

1. Mount the scanner, connect it to the power source and ethernet.

2. Run the installer packed in the archive and follow the on-screen instructions

3. Run PhoXiControl.exe using shortcut or under Program Files/PhotoneoPhoXiControl/bin

CAD data

Contains 3D Scanner body and its scanning volume as a solid object.

Available CAD for download:

PhoXi Scanner S + scanning volume
PhoXi Scanner M + scanning volume
PhoXi Scanner L + scanning volume

ScanningVolume.png

Mounting plate drawing

MountingPlateDrawing.png