Line 2: Line 2:
 
{| class="wikitable"
 
{| class="wikitable"
 
|+Projection unit
 
|+Projection unit
 +
|-
 +
|Light source
 +
|Visible red light (laser)
 
|-
 
|-
 
|Wavelength
 
|Wavelength
Line 7: Line 10:
 
|-
 
|-
 
|Laser class
 
|Laser class
| style="text-align:right;" | 3R
+
| style="text-align:right;" | 3R (IEC / EN 60825-1, 2014)
 
|-
 
|-
 
|Projection angle horizontal
 
|Projection angle horizontal

Revision as of 12:09, 24 January 2017

General specification

Projection unit
Light source Visible red light (laser)
Wavelength 638nm
Laser class 3R (IEC / EN 60825-1, 2014)
Projection angle horizontal 47.5° ±1°
Projection angle vertical 36.0° ±2°

For model/size specific parameters see our product showcase.

Connectivity

Connectivity v1.png

Installation

1. Mount the scanner, connect it to the power source and ethernet.

2. Run the installer packed in the archive and follow the on-screen instructions

3. Run PhoXiControl.exe using shortcut or under Program Files/PhotoneoPhoXiControl/bin

CAD data

Contains 3D Scanner body and its scanning volume as a solid object:

PhoXi Scanner S ScannerS+Volume.step
PhoXi Scanner M ScannerM+Volume.step
PhoXi Scanner L ScannerL+Volume.step

ScanningVolume.png

Mounting plate drawing

MountingPlateDrawing.png