Following tutorial provides step by step guide how to configure your ABB IRC5 controller and install RAPID interface for Photoneo Binpicking Solution.
 +
 +
This tutorial was originally written for  RobotWare v.6.x and higher systems, however it should also work with older versions with minor changes. 
  
 
=== 2.1 Network configuration ===
 
=== 2.1 Network configuration ===
  
Turn on the IRC5 Controller and wait for '''Menu screen''' to appear on the pendant and select '''Control Panel''' option (RobotWare v.6. and higher is used within this tutorial):
+
Turn on the IRC5 Controller, wait for Initialization Screen to appear, open '''Menu screen'''and select '''Control Panel''' option :
 
   
 
   
  
Line 23: Line 27:
  
  
Go to '''Controller Settings'''
+
On the Control Panel pane, select '''Controller Settings'''
 +
 
  
 
[[File:ABB_pendant_control_panel.png]]  
 
[[File:ABB_pendant_control_panel.png]]  
  
  
Select '''Settings''' and '''Network'''
+
Select '''Settings''' and choose '''Network''' option
  
  
 
[[File:ABB pendant network.png]]
 
[[File:ABB pendant network.png]]
  
 +
 +
Network settings window should appear. Use the '''touch panel keypad''' to set IP address of IRC5 WAN port.
 +
 +
 +
[[File:ABB pendant IP setup.png]]
  
 +
 +
Press '''OK button''' and restart the controller to apply new settings
 +
 +
 +
[[File:ABB pendant restart.png]]
  
  
NOTE: If you need to change existing IP settings, follow [https://www.robot-forum.com/robotforum/abb-robot-forum/setting-ip-address-of-irc5-controller this thread]
 
  
 
=== 2.2 Use Robot Studio to Connect to IRC5 Controller ===
 
=== 2.2 Use Robot Studio to Connect to IRC5 Controller ===
  
 
Set your local PC network settings to DHCP, plug Ethernet cable to Service Port of IRC5 Controller and launch Robot Studio.
 
Set your local PC network settings to DHCP, plug Ethernet cable to Service Port of IRC5 Controller and launch Robot Studio.
 +
 +
For direct connection to Robot Controller, select '''Controller''' tab and '''One Click Connect''' option.
 +
 +
[[File:Robot studio connect.png]]
 +
 +
 +
As a first step in installation Photoneo ABB Interface, you need to copy RAPID files from your PC to the Robot Controller
 +
 +
You can use USB stick and copy files directly from the pendant, however the most convenient way is to use Robot Studio internal File Transfer tool.
 +
 +
Go to '''Controller''' tab and select '''File Transfer''' tool from the menu
 +
 +
 +
[[File: Robot studio file transfer.png]]
 +
 +
 +
  
 
=== 2.3 Configuring a I/O ===
 
=== 2.3 Configuring a I/O ===

Revision as of 16:16, 18 January 2018

1. Prerequisities

Following conditions must be met:

- (616-6) PC Interface Module available

- (672-1) Multitasking Module available

- RoboTWareOS 5.13 and higher

+

- Robot Studio Installation (v.6.04 is recommended)

2. ABB Controller setup

Following tutorial provides step by step guide how to configure your ABB IRC5 controller and install RAPID interface for Photoneo Binpicking Solution.

This tutorial was originally written for RobotWare v.6.x and higher systems, however it should also work with older versions with minor changes.

2.1 Network configuration

Turn on the IRC5 Controller, wait for Initialization Screen to appear, open Menu screenand select Control Panel option :


ABB pendant menu RW6.png


On the Control Panel pane, select Controller Settings


ABB pendant control panel.png


Select Settings and choose Network option


ABB pendant network.png


Network settings window should appear. Use the touch panel keypad to set IP address of IRC5 WAN port.


ABB pendant IP setup.png


Press OK button and restart the controller to apply new settings


ABB pendant restart.png


2.2 Use Robot Studio to Connect to IRC5 Controller

Set your local PC network settings to DHCP, plug Ethernet cable to Service Port of IRC5 Controller and launch Robot Studio.

For direct connection to Robot Controller, select Controller tab and One Click Connect option.

Robot studio connect.png


As a first step in installation Photoneo ABB Interface, you need to copy RAPID files from your PC to the Robot Controller

You can use USB stick and copy files directly from the pendant, however the most convenient way is to use Robot Studio internal File Transfer tool.

Go to Controller tab and select File Transfer tool from the menu


Robot studio file transfer.png



2.3 Configuring a I/O

2.3.1 Preparation

Assemble cables (tall box on palette with controller), specifically XP1, XP13, XP2 to the bottom side of controller, with their respective connectors on the base of robot.

2.3.2 Setting up I/O

Various links are accessible on panel inside cabinet. These signals are wired throught XS/XP13 connector underneath the cabinet, throught connection in base of robot to R1(2).CP and R1(2).CS. XT6/6.1 signals 1 to 4 are usually used to power your device (4x1mm2) with link to R1(2).CP and connectors XT5.1, XT5.2 and XT5.3 are used to provide signals for your accessories carried by robot with link to R1(2).CS.

2.3.3 Accessing signals in program

Usually a I/O slave is supplied with robotic controller. If not install one inside cabinet and in Configuration - I/O System tab. Once completed a list of device’s Inputs/Outputs may appear in Signals tab. Configure them according to their specific purpose. A example of signal configuration is shown below:

Signals tab robot studio.PNG