http://wiki.photoneo.com/api.php?action=feedcontributions&user=Matus&feedformat=atom3D scanning Knowledge base - Photoneo wiki - User contributions [en]2024-03-29T07:02:03ZUser contributionsMediaWiki 1.27.0http://wiki.photoneo.com/index.php?title=PhoXi_3D_scanners_family&diff=900PhoXi 3D scanners family2018-07-19T15:19:15Z<p>Matus: /* Connectivity */</p>
<hr />
<div><br />
This page contains technical description of PhoXi 3D Scanners. For scanning guide, see '''[[Scanning best practices]]'''.<br />
<br />
== General specification ==<br />
{| class="wikitable"<br />
|+Projection unit<br />
|-<br />
|Light source<br />
| style="text-align:right;" | Visible red light (laser)<br />
|-<br />
|Wavelength<br />
| style="text-align:right;" | 638nm<br />
|-<br />
|Laser class<br />
| style="text-align:right;" | 3R (IEC / EN 60825-1, 2014)<br />
|-<br />
|Peak / CW Power<br />
| style="text-align:right;" | 314uW<br />
|-<br />
|Pulse Energy<br />
| style="text-align:right;" | 382nJ<br />
|-<br />
|Pulse Length<br />
| style="text-align:right;" | 960us<br />
|-<br />
|Projection angle horizontal<br />
| style="text-align:right;" | 47.5° ±1°<br />
|-<br />
|Projection angle vertical<br />
| style="text-align:right;" | 36.0° ±2°<br />
|}<br />
<br />
For model/size specific parameters see our '''[http://www.photoneo.com/product-showcase/phoxi_3d_scanners/ product showcase]'''.<br />
<br />
=== Specification Parameters Explanation ===<br />
<br />
;Depth Map resolution<br />
:Maximum number of measured points (the resolution of camera sensor)<br />
<br />
;Point size<br />
:The distance between two measured points on the plane perpendicular to the camera in the focus distance from the camera. <br />
:[[File:Scanning-distance-to-point-size-and-z-noise.png|thumb|500px|Relation of point size to scanning distance]]<br />
<br />
;Absolute accuracy<br />
:The accuracy of point measurement as the result of device calibration (can be understood as the space deformation). It is the standard deviation of the measurement error in the whole measuring range of the device.<br />
<br />
;Z noise<br />
:The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution. Can be understood as temporal noise.<br />
<br />
;FPS<br />
:Maximum number of triggered frames per second, in fastest acquisition mode<br />
<br />
;Data acquisition time - best case<br />
:Fastest possible acquisition time<br />
<br />
;Data acquisition time - worst case<br />
:Longest expected acquisition time (bad lighting conditions, dark shiny objects)<br />
<br />
;3D points throughput<br />
:Number of 3D points that can be reconstructed in a second in sequential scans<br />
<br />
== Connectivity ==<br />
[[File:Connectivity v1.png|800x600px]]<br />
<br />
{| class="wikitable"<br />
! colspan="2" | Status LEDs meaning<br />
|-<br />
| ⚫ Power status<br />
Power cable connected<br />
| ⚫ Processing unit connected<br /><br />
On => Suitable power connected<br /><br />
Off => Under/overvoltage, overcurrent<br />
|-<br />
| ⚫ Reserved<br />
-<br />
| ⚫ Reserved<br />
-<br />
|-<br />
| ⚫ Ethernet speed<br /><br />
Off => Indicates 1 Gbps<br /><br />
On => Indicates 100 Mbps<br />
| ⚫ Ethernet activity<br /><br />
Off => Link is down<br /><br />
Flashing Green => Link is up, with activity<br /><br />
Steady Green => Link is up, no activity<br />
|}<br />
<br />
== CAD data ==<br />
Contains 3D Scanner body and its scanning volume as a solid object. <br />
<br />
Available CAD models for download:<br />
<br />
{| class="wikitable" style="text-align:center; padding: 1em !important"<br />
! Device <br />
! Mounting space coordinate space <br />
! Camera coordinate space<br />
|- <br />
| PhoXi 3D Scanner XS <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.mount_origin.zip XS - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.cam_origin.zip XS - camera space]<br />
|-<br />
| PhoXi 3D Scanner S <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.mount_origin.zip S - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.cam_origin.zip S - camera space]<br />
|-<br />
| PhoXi 3D Scanner M <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.mount_origin.zip - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.cam_origin.zip M - camera space]<br />
|-<br />
| PhoXi 3D Scanner L <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.mount_origin.zip L - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.cam_origin.zip L - camera space]<br />
|-<br />
| PhoXi 3D Scanner XL <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.mount_origin.zip XL - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.cam_origin.zip XL - camera space]<br />
|-<br />
|<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.mount_origin.zip All in mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.cam_origin.zip All in camera space]<br />
|}<br />
<br />
Note: Camera coordinate space is only approximate. <br />
<br />
[[File:scanningVolume.png|600px]]<br />
<br />
== Mounting plate drawing ==<br />
[[File:MountingPlateDrawing.png|800px]]</div>Matushttp://wiki.photoneo.com/index.php?title=PhoXi_3D_scanners_family&diff=885PhoXi 3D scanners family2018-07-19T13:49:17Z<p>Matus: /* Connectivity */</p>
<hr />
<div><br />
This page contains technical description of PhoXi 3D Scanners. For scanning guide, see '''[[Scanning best practices]]'''.<br />
<br />
== General specification ==<br />
{| class="wikitable"<br />
|+Projection unit<br />
|-<br />
|Light source<br />
| style="text-align:right;" | Visible red light (laser)<br />
|-<br />
|Wavelength<br />
| style="text-align:right;" | 638nm<br />
|-<br />
|Laser class<br />
| style="text-align:right;" | 3R (IEC / EN 60825-1, 2014)<br />
|-<br />
|Peak / CW Power<br />
| style="text-align:right;" | 314uW<br />
|-<br />
|Pulse Energy<br />
| style="text-align:right;" | 382nJ<br />
|-<br />
|Pulse Length<br />
| style="text-align:right;" | 960us<br />
|-<br />
|Projection angle horizontal<br />
| style="text-align:right;" | 47.5° ±1°<br />
|-<br />
|Projection angle vertical<br />
| style="text-align:right;" | 36.0° ±2°<br />
|}<br />
<br />
For model/size specific parameters see our '''[http://www.photoneo.com/product-showcase/phoxi_3d_scanners/ product showcase]'''.<br />
<br />
=== Specification Parameters Explanation ===<br />
<br />
;Depth Map resolution<br />
:Maximum number of measured points (the resolution of camera sensor)<br />
<br />
;Point size<br />
:The distance between two measured points on the plane perpendicular to the camera in the focus distance from the camera. <br />
:[[File:Scanning-distance-to-point-size-and-z-noise.png|thumb|500px|Relation of point size to scanning distance]]<br />
<br />
;Absolute accuracy<br />
:The accuracy of point measurement as the result of device calibration (can be understood as the space deformation). It is the standard deviation of the measurement error in the whole measuring range of the device.<br />
<br />
;Z noise<br />
:The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution. Can be understood as temporal noise.<br />
<br />
;FPS<br />
:Maximum number of triggered frames per second, in fastest acquisition mode<br />
<br />
;Data acquisition time - best case<br />
:Fastest possible acquisition time<br />
<br />
;Data acquisition time - worst case<br />
:Longest expected acquisition time (bad lighting conditions, dark shiny objects)<br />
<br />
;3D points throughput<br />
:Number of 3D points that can be reconstructed in a second in sequential scans<br />
<br />
== Connectivity ==<br />
[[File:Connectivity v1.png|800x600px]]<br />
<br />
{| class="wikitable"<br />
! colspan="2" | Status LEDs on back side matching the arrangement shown below<br />
|-<br />
| ⚫ Power status<br />
Power cable connected<br />
| ⚫ Processing unit connected<br /><br />
On => Suitable power connected<br /><br />
Off => Under/overvoltage, overcurrent<br />
|-<br />
| ⚫ Reserved<br />
-<br />
| ⚫ Reserved<br />
-<br />
|-<br />
| ⚫ Ethernet speed<br /><br />
Off => Indicates 1 Gbps<br /><br />
On => Indicates 100 Mbps<br />
| ⚫ Ethernet activity<br /><br />
Off => Link is down<br /><br />
Flashing Green => Link is up, with activity<br /><br />
Steady Green => Link is up, no activity<br />
|}<br />
<br />
== CAD data ==<br />
Contains 3D Scanner body and its scanning volume as a solid object. <br />
<br />
Available CAD models for download:<br />
<br />
{| class="wikitable" style="text-align:center; padding: 1em !important"<br />
! Device <br />
! Mounting space coordinate space <br />
! Camera coordinate space<br />
|- <br />
| PhoXi 3D Scanner XS <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.mount_origin.zip XS - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.cam_origin.zip XS - camera space]<br />
|-<br />
| PhoXi 3D Scanner S <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.mount_origin.zip S - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.cam_origin.zip S - camera space]<br />
|-<br />
| PhoXi 3D Scanner M <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.mount_origin.zip - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.cam_origin.zip M - camera space]<br />
|-<br />
| PhoXi 3D Scanner L <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.mount_origin.zip L - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.cam_origin.zip L - camera space]<br />
|-<br />
| PhoXi 3D Scanner XL <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.mount_origin.zip XL - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.cam_origin.zip XL - camera space]<br />
|-<br />
|<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.mount_origin.zip All in mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.cam_origin.zip All in camera space]<br />
|}<br />
<br />
Note: Camera coordinate space is only approximate. <br />
<br />
[[File:scanningVolume.png|600px]]<br />
<br />
== Mounting plate drawing ==<br />
[[File:MountingPlateDrawing.png|800px]]</div>Matushttp://wiki.photoneo.com/index.php?title=PhoXi_3D_scanners_family&diff=884PhoXi 3D scanners family2018-07-19T13:44:55Z<p>Matus: /* Connectivity */</p>
<hr />
<div><br />
This page contains technical description of PhoXi 3D Scanners. For scanning guide, see '''[[Scanning best practices]]'''.<br />
<br />
== General specification ==<br />
{| class="wikitable"<br />
|+Projection unit<br />
|-<br />
|Light source<br />
| style="text-align:right;" | Visible red light (laser)<br />
|-<br />
|Wavelength<br />
| style="text-align:right;" | 638nm<br />
|-<br />
|Laser class<br />
| style="text-align:right;" | 3R (IEC / EN 60825-1, 2014)<br />
|-<br />
|Peak / CW Power<br />
| style="text-align:right;" | 314uW<br />
|-<br />
|Pulse Energy<br />
| style="text-align:right;" | 382nJ<br />
|-<br />
|Pulse Length<br />
| style="text-align:right;" | 960us<br />
|-<br />
|Projection angle horizontal<br />
| style="text-align:right;" | 47.5° ±1°<br />
|-<br />
|Projection angle vertical<br />
| style="text-align:right;" | 36.0° ±2°<br />
|}<br />
<br />
For model/size specific parameters see our '''[http://www.photoneo.com/product-showcase/phoxi_3d_scanners/ product showcase]'''.<br />
<br />
=== Specification Parameters Explanation ===<br />
<br />
;Depth Map resolution<br />
:Maximum number of measured points (the resolution of camera sensor)<br />
<br />
;Point size<br />
:The distance between two measured points on the plane perpendicular to the camera in the focus distance from the camera. <br />
:[[File:Scanning-distance-to-point-size-and-z-noise.png|thumb|500px|Relation of point size to scanning distance]]<br />
<br />
;Absolute accuracy<br />
:The accuracy of point measurement as the result of device calibration (can be understood as the space deformation). It is the standard deviation of the measurement error in the whole measuring range of the device.<br />
<br />
;Z noise<br />
:The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution. Can be understood as temporal noise.<br />
<br />
;FPS<br />
:Maximum number of triggered frames per second, in fastest acquisition mode<br />
<br />
;Data acquisition time - best case<br />
:Fastest possible acquisition time<br />
<br />
;Data acquisition time - worst case<br />
:Longest expected acquisition time (bad lighting conditions, dark shiny objects)<br />
<br />
;3D points throughput<br />
:Number of 3D points that can be reconstructed in a second in sequential scans<br />
<br />
== Connectivity ==<br />
[[File:Connectivity v1.png|800x600px]]<br />
<br />
{| class="wikitable"<br />
! colspan="2" | Status LEDs on back side matching the arrangement shown below<br />
|-<br />
| ⚫ Power status<br />
Power cable connected<br />
| ⚫ Processing unit connected<br />
On => Suitable power connected<br />
Off => Under/overvoltage, overcurrent<br />
|-<br />
| ⚫ Reserved<br />
-<br />
| ⚫ Reserved<br />
-<br />
|-<br />
| ⚫ Ethernet speed<br />
Off => Indicates 1 Gbps<br />
On => Indicates 100 Mbps<br />
| ⚫ Ethernet activity<br />
Off => Link is down<br />
Flashing Green => Link is up, with activity<br />
Steady Green => Link is up, no activity<br />
|}<br />
<br />
== CAD data ==<br />
Contains 3D Scanner body and its scanning volume as a solid object. <br />
<br />
Available CAD models for download:<br />
<br />
{| class="wikitable" style="text-align:center; padding: 1em !important"<br />
! Device <br />
! Mounting space coordinate space <br />
! Camera coordinate space<br />
|- <br />
| PhoXi 3D Scanner XS <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.mount_origin.zip XS - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.cam_origin.zip XS - camera space]<br />
|-<br />
| PhoXi 3D Scanner S <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.mount_origin.zip S - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.cam_origin.zip S - camera space]<br />
|-<br />
| PhoXi 3D Scanner M <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.mount_origin.zip - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.cam_origin.zip M - camera space]<br />
|-<br />
| PhoXi 3D Scanner L <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.mount_origin.zip L - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.cam_origin.zip L - camera space]<br />
|-<br />
| PhoXi 3D Scanner XL <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.mount_origin.zip XL - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.cam_origin.zip XL - camera space]<br />
|-<br />
|<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.mount_origin.zip All in mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.cam_origin.zip All in camera space]<br />
|}<br />
<br />
Note: Camera coordinate space is only approximate. <br />
<br />
[[File:scanningVolume.png|600px]]<br />
<br />
== Mounting plate drawing ==<br />
[[File:MountingPlateDrawing.png|800px]]</div>Matushttp://wiki.photoneo.com/index.php?title=PhoXi_3D_scanners_family&diff=883PhoXi 3D scanners family2018-07-19T13:42:43Z<p>Matus: /* Connectivity */</p>
<hr />
<div><br />
This page contains technical description of PhoXi 3D Scanners. For scanning guide, see '''[[Scanning best practices]]'''.<br />
<br />
== General specification ==<br />
{| class="wikitable"<br />
|+Projection unit<br />
|-<br />
|Light source<br />
| style="text-align:right;" | Visible red light (laser)<br />
|-<br />
|Wavelength<br />
| style="text-align:right;" | 638nm<br />
|-<br />
|Laser class<br />
| style="text-align:right;" | 3R (IEC / EN 60825-1, 2014)<br />
|-<br />
|Peak / CW Power<br />
| style="text-align:right;" | 314uW<br />
|-<br />
|Pulse Energy<br />
| style="text-align:right;" | 382nJ<br />
|-<br />
|Pulse Length<br />
| style="text-align:right;" | 960us<br />
|-<br />
|Projection angle horizontal<br />
| style="text-align:right;" | 47.5° ±1°<br />
|-<br />
|Projection angle vertical<br />
| style="text-align:right;" | 36.0° ±2°<br />
|}<br />
<br />
For model/size specific parameters see our '''[http://www.photoneo.com/product-showcase/phoxi_3d_scanners/ product showcase]'''.<br />
<br />
=== Specification Parameters Explanation ===<br />
<br />
;Depth Map resolution<br />
:Maximum number of measured points (the resolution of camera sensor)<br />
<br />
;Point size<br />
:The distance between two measured points on the plane perpendicular to the camera in the focus distance from the camera. <br />
:[[File:Scanning-distance-to-point-size-and-z-noise.png|thumb|500px|Relation of point size to scanning distance]]<br />
<br />
;Absolute accuracy<br />
:The accuracy of point measurement as the result of device calibration (can be understood as the space deformation). It is the standard deviation of the measurement error in the whole measuring range of the device.<br />
<br />
;Z noise<br />
:The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution. Can be understood as temporal noise.<br />
<br />
;FPS<br />
:Maximum number of triggered frames per second, in fastest acquisition mode<br />
<br />
;Data acquisition time - best case<br />
:Fastest possible acquisition time<br />
<br />
;Data acquisition time - worst case<br />
:Longest expected acquisition time (bad lighting conditions, dark shiny objects)<br />
<br />
;3D points throughput<br />
:Number of 3D points that can be reconstructed in a second in sequential scans<br />
<br />
== Connectivity ==<br />
[[File:Connectivity v1.png|800x600px]]<br />
<br />
{| class="wikitable"<br />
! colspan="2" | Status LEDs on back side matching the arrangement shown below<br />
|-<br />
| ⚫ Power status<br />
Power cable connected<br />
| ⚫ Processing unit connected<br />
On => Suitable power connected <br />
Off => Under/overvoltage, overcurrent<br />
|-<br />
| ⚫ Reserved<br />
-<br />
| ⚫ Reserved<br />
-<br />
|-<br />
| ⚫ Ethernet speed<br />
Off => Indicates 1 Gbps <br />
On => Indicates 100 Mbps<br />
| ⚫ Ethernet activity<br />
Off => Link is down<br />
Flashing Green => Link is up, with activity<br />
Steady Green => Link is up, no activity<br />
|}<br />
<br />
== CAD data ==<br />
Contains 3D Scanner body and its scanning volume as a solid object. <br />
<br />
Available CAD models for download:<br />
<br />
{| class="wikitable" style="text-align:center; padding: 1em !important"<br />
! Device <br />
! Mounting space coordinate space <br />
! Camera coordinate space<br />
|- <br />
| PhoXi 3D Scanner XS <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.mount_origin.zip XS - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.cam_origin.zip XS - camera space]<br />
|-<br />
| PhoXi 3D Scanner S <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.mount_origin.zip S - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.cam_origin.zip S - camera space]<br />
|-<br />
| PhoXi 3D Scanner M <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.mount_origin.zip - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.cam_origin.zip M - camera space]<br />
|-<br />
| PhoXi 3D Scanner L <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.mount_origin.zip L - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.cam_origin.zip L - camera space]<br />
|-<br />
| PhoXi 3D Scanner XL <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.mount_origin.zip XL - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.cam_origin.zip XL - camera space]<br />
|-<br />
|<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.mount_origin.zip All in mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.cam_origin.zip All in camera space]<br />
|}<br />
<br />
Note: Camera coordinate space is only approximate. <br />
<br />
[[File:scanningVolume.png|600px]]<br />
<br />
== Mounting plate drawing ==<br />
[[File:MountingPlateDrawing.png|800px]]</div>Matushttp://wiki.photoneo.com/index.php?title=PhoXi_3D_scanners_family&diff=880PhoXi 3D scanners family2018-07-19T13:39:12Z<p>Matus: /* Connectivity */</p>
<hr />
<div><br />
This page contains technical description of PhoXi 3D Scanners. For scanning guide, see '''[[Scanning best practices]]'''.<br />
<br />
== General specification ==<br />
{| class="wikitable"<br />
|+Projection unit<br />
|-<br />
|Light source<br />
| style="text-align:right;" | Visible red light (laser)<br />
|-<br />
|Wavelength<br />
| style="text-align:right;" | 638nm<br />
|-<br />
|Laser class<br />
| style="text-align:right;" | 3R (IEC / EN 60825-1, 2014)<br />
|-<br />
|Peak / CW Power<br />
| style="text-align:right;" | 314uW<br />
|-<br />
|Pulse Energy<br />
| style="text-align:right;" | 382nJ<br />
|-<br />
|Pulse Length<br />
| style="text-align:right;" | 960us<br />
|-<br />
|Projection angle horizontal<br />
| style="text-align:right;" | 47.5° ±1°<br />
|-<br />
|Projection angle vertical<br />
| style="text-align:right;" | 36.0° ±2°<br />
|}<br />
<br />
For model/size specific parameters see our '''[http://www.photoneo.com/product-showcase/phoxi_3d_scanners/ product showcase]'''.<br />
<br />
=== Specification Parameters Explanation ===<br />
<br />
;Depth Map resolution<br />
:Maximum number of measured points (the resolution of camera sensor)<br />
<br />
;Point size<br />
:The distance between two measured points on the plane perpendicular to the camera in the focus distance from the camera. <br />
:[[File:Scanning-distance-to-point-size-and-z-noise.png|thumb|500px|Relation of point size to scanning distance]]<br />
<br />
;Absolute accuracy<br />
:The accuracy of point measurement as the result of device calibration (can be understood as the space deformation). It is the standard deviation of the measurement error in the whole measuring range of the device.<br />
<br />
;Z noise<br />
:The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution. Can be understood as temporal noise.<br />
<br />
;FPS<br />
:Maximum number of triggered frames per second, in fastest acquisition mode<br />
<br />
;Data acquisition time - best case<br />
:Fastest possible acquisition time<br />
<br />
;Data acquisition time - worst case<br />
:Longest expected acquisition time (bad lighting conditions, dark shiny objects)<br />
<br />
;3D points throughput<br />
:Number of 3D points that can be reconstructed in a second in sequential scans<br />
<br />
== Connectivity ==<br />
[[File:Connectivity v1.png|800x600px]]<br />
<br />
Status LEDs on the back side, matching the arrangement shown below.<br />
<br />
{| class="wikitable"<br />
! ⚫ Power status<br />
Power cable connected<br />
! ⚫ Processing unit connected<br />
On => Suitable power connected <br />
Off => Under/overvoltage, overcurrent<br />
|-<br />
| ⚫ Reserved<br />
-<br />
| ⚫ Reserved<br />
-<br />
|-<br />
| ⚫ Ethernet speed<br />
Off => Indicates 1 Gbps <br />
On => Indicates 100 Mbps<br />
| ⚫ Ethernet activity<br />
Off => Link is down<br />
Flashing Green => Link is up, with activity<br />
Steady Green => Link is up, no activity<br />
|}<br />
<br />
== CAD data ==<br />
Contains 3D Scanner body and its scanning volume as a solid object. <br />
<br />
Available CAD models for download:<br />
<br />
{| class="wikitable" style="text-align:center; padding: 1em !important"<br />
! Device <br />
! Mounting space coordinate space <br />
! Camera coordinate space<br />
|- <br />
| PhoXi 3D Scanner XS <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.mount_origin.zip XS - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.cam_origin.zip XS - camera space]<br />
|-<br />
| PhoXi 3D Scanner S <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.mount_origin.zip S - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.cam_origin.zip S - camera space]<br />
|-<br />
| PhoXi 3D Scanner M <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.mount_origin.zip - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.cam_origin.zip M - camera space]<br />
|-<br />
| PhoXi 3D Scanner L <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.mount_origin.zip L - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.cam_origin.zip L - camera space]<br />
|-<br />
| PhoXi 3D Scanner XL <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.mount_origin.zip XL - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.cam_origin.zip XL - camera space]<br />
|-<br />
|<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.mount_origin.zip All in mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.cam_origin.zip All in camera space]<br />
|}<br />
<br />
Note: Camera coordinate space is only approximate. <br />
<br />
[[File:scanningVolume.png|600px]]<br />
<br />
== Mounting plate drawing ==<br />
[[File:MountingPlateDrawing.png|800px]]</div>Matushttp://wiki.photoneo.com/index.php?title=PhoXi_3D_scanners_family&diff=877PhoXi 3D scanners family2018-07-19T13:26:12Z<p>Matus: /* Connectivity */</p>
<hr />
<div><br />
This page contains technical description of PhoXi 3D Scanners. For scanning guide, see '''[[Scanning best practices]]'''.<br />
<br />
== General specification ==<br />
{| class="wikitable"<br />
|+Projection unit<br />
|-<br />
|Light source<br />
| style="text-align:right;" | Visible red light (laser)<br />
|-<br />
|Wavelength<br />
| style="text-align:right;" | 638nm<br />
|-<br />
|Laser class<br />
| style="text-align:right;" | 3R (IEC / EN 60825-1, 2014)<br />
|-<br />
|Peak / CW Power<br />
| style="text-align:right;" | 314uW<br />
|-<br />
|Pulse Energy<br />
| style="text-align:right;" | 382nJ<br />
|-<br />
|Pulse Length<br />
| style="text-align:right;" | 960us<br />
|-<br />
|Projection angle horizontal<br />
| style="text-align:right;" | 47.5° ±1°<br />
|-<br />
|Projection angle vertical<br />
| style="text-align:right;" | 36.0° ±2°<br />
|}<br />
<br />
For model/size specific parameters see our '''[http://www.photoneo.com/product-showcase/phoxi_3d_scanners/ product showcase]'''.<br />
<br />
=== Specification Parameters Explanation ===<br />
<br />
;Depth Map resolution<br />
:Maximum number of measured points (the resolution of camera sensor)<br />
<br />
;Point size<br />
:The distance between two measured points on the plane perpendicular to the camera in the focus distance from the camera. <br />
:[[File:Scanning-distance-to-point-size-and-z-noise.png|thumb|500px|Relation of point size to scanning distance]]<br />
<br />
;Absolute accuracy<br />
:The accuracy of point measurement as the result of device calibration (can be understood as the space deformation). It is the standard deviation of the measurement error in the whole measuring range of the device.<br />
<br />
;Z noise<br />
:The standard deviation of the noise (measured on a diffuse surface with 80 percent albedo). The noise level describes the quality of the sensor to capture local surface details. The noise distribution of our sensor is similar to Gaussian distribution. Can be understood as temporal noise.<br />
<br />
;FPS<br />
:Maximum number of triggered frames per second, in fastest acquisition mode<br />
<br />
;Data acquisition time - best case<br />
:Fastest possible acquisition time<br />
<br />
;Data acquisition time - worst case<br />
:Longest expected acquisition time (bad lighting conditions, dark shiny objects)<br />
<br />
;3D points throughput<br />
:Number of 3D points that can be reconstructed in a second in sequential scans<br />
<br />
== Connectivity ==<br />
[[File:Connectivity v1.png|800x600px]]<br />
<br />
Status LEDs on the back side, matching the arrangement shown below.<br />
<br />
⚫ Power status ⚫ Processing unit connected<br />
Power cable connected On => Suitable power connected.<br />
Off => Under/Overvoltage, Overcurrent<br />
<br />
<br />
⚫ Reserved ⚫ Reserved<br />
- -<br />
<br />
<br />
<br />
⚫ Ethernet speed ⚫ Ethernet activity<br />
Off => Indicates 1Gbps Off => Link is down<br />
On => Indicates 100Mbps Flashing Green => Link is up, with activity<br />
Steady Green => Link is up, no activity<br />
<br />
== CAD data ==<br />
Contains 3D Scanner body and its scanning volume as a solid object. <br />
<br />
Available CAD models for download:<br />
<br />
{| class="wikitable" style="text-align:center; padding: 1em !important"<br />
! Device <br />
! Mounting space coordinate space <br />
! Camera coordinate space<br />
|- <br />
| PhoXi 3D Scanner XS <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.mount_origin.zip XS - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XS.cam_origin.zip XS - camera space]<br />
|-<br />
| PhoXi 3D Scanner S <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.mount_origin.zip S - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_S.cam_origin.zip S - camera space]<br />
|-<br />
| PhoXi 3D Scanner M <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.mount_origin.zip - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_M.cam_origin.zip M - camera space]<br />
|-<br />
| PhoXi 3D Scanner L <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.mount_origin.zip L - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_L.cam_origin.zip L - camera space]<br />
|-<br />
| PhoXi 3D Scanner XL <br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.mount_origin.zip XL - mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/scan_volume_XL.cam_origin.zip XL - camera space]<br />
|-<br />
|<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.mount_origin.zip All in mounting space]<br />
| [http://photoneo.com/files/cad/Scanner+Volume/PhoXi3DScanner.cam_origin.zip All in camera space]<br />
|}<br />
<br />
Note: Camera coordinate space is only approximate. <br />
<br />
[[File:scanningVolume.png|600px]]<br />
<br />
== Mounting plate drawing ==<br />